Fire Sprinkler Riser Room Location
Thereafter the riser goes to floor 1 and above.
Fire sprinkler riser room location. Automatic sprinkler systems. The location of the fire department connections shall be approved by the fire marshal. Automatic sprinkler systems 903 2 11 1 1 opening dimensions and access. Openings shall have a minimum dimension of not less than 30 inches 762 mm.
2018 code 901 4 6 4 901 4 6 1 access. 2 rooms housing the control valves and sprinkler riser s shall be located in such a manner as to allow the door to exit directly to the outside of the structure and be a separate and distinct room. Such openings shall be accessible to the fire department from the exterior and shall not be obstructed in a manner that fire fighting or rescue cannot be accomplished from the exterior. But fire code also gives property owners some leeway in determining their exact location within a building.
Where the reliance on a fire sprinkler system may not be as strong a designated room may not be provided or necessary. Automatic sprinkler system risers fire pumps and controllers shall be provided with ready access. Then it conveys that water to the network of pipes running to fire sprinkler heads. If the fire service lead in is more than 100 f t in total length the assembly.
Where lo cated in a fire pump room or automatic sprinkler system riser room the door shall be permitted to be locked provided the key is available at all. Location of fire riser. Tomatic sprinkler system riser rooms and fire pump rooms. Mckinney fire department fire marshal s office automatic fire sprinkler system s 2200 taylor burk mckinney tx 75071 page 3 of 5 be located within the riser room.
A system s risers may be in a hallway or on the outside of a building. Risers and components that typically attach to them are essential to normal sprinkler system operations including. You need to have this discussion with the ahj. The municipal water enters the building and goes through the backflow preventer and then into the fire pump both being located in the fire pump room.
Sprinkler riser rooms must be located on the ground floor with a door that s directly accessible from the outside. Each riser taps into a permanent source of water such as a pipe connected to the city water system a water tank or reservoir. On the first floor there is a floor control valve with drain. Neither the nfpa nor the icc international code council requires that a proper riser room be provided for a fire sprinkler system s risers.