Fire Rated Garage Door Requirements
Solid or honeycomb core steel at least 1 3 8 thick.
Fire rated garage door requirements. This classification covers most residential requirements and can also meet commercial requirements for 20 minute. While the six panel door shown below gets awfully thin at the panels this is still a 20 minute fire rated door so there s nothing wrong with it being used. And best of all simpson 20 minute fire rated doors match up perfectly with virtually any simpson interior panel. Solid wood at least 1 3 8 thick.
For instance there are fire rated doors that have a 20 minute several hours rating and they can be selected to meet fire department code requirements for residential spaces check your condo or townhouse local building codes for any requirements of fire rated entry or house to garage doors. Commercial fire rated door requirements are typically determined by the fire rating of the wall and use of the door. Other openings between the garage and the residence shall be equipped with solid wood doors not less than 1 3 8 35 mm in thickness solid or honeycomb core steel doors not less than 1 3 8 35 mm thick or 20 minute fire rated doors. We check the bug on the glass and it is usually safety glass but have yet to find one with glass that is fire rated.
A solid wood door not less than 1 3 8 inches thick a solid or honeycomb core steel doors not less than 1 3 8 inches thick or a 20 minute fire rated door with a self closing device. Designed to close automatically in the event of a fire or alarmed event our fire rated doors are available for service door and counter applications in commercial industrial institutional and retail projects. Fire door requirements are set by the national fire protection association and these requirements have been incorporated into most local building codes in the united states with little to no modification. Not all doors in a commercial building need to be fire rated.
Simpson 20 minute fire rated doors comply with major code requirements for the 20 minute fire safety classification. Metal fire doors can attain ratings up to 3 hours where wood fire doors can be rated up to 90 minutes. Openings from a private garage directly into a room used for sleeping purposes shall not be permitted. A remodeler doing a flip house changes out all the doors in the home to update the interior and replaces the old door to the garage with a hollow core interior door.
When there is a living area habitable space above the garage the ceiling requirement ramps up to 5 8 type x fire rated drywall. The door shown below is an example. Doors between a house and a garage can be one of three types take your pick. We offer a wide array of rolling steel doors to meet the most demanding fire safety standards unusual opening sizes and discerning aesthetic requirements.