Fire Door Hinges British Standard
Digit 3 door size mass.
Fire door hinges british standard. Fire doors should be regularly inspected for damage that may prevent the door from performing in the event of a fire. Bs 8214 2016 code of practice or fire door assemblies clause 14 decoration. Firefighter s tips for fire door installation and use there are some simple must knows when it comes to fire doors and their safe use and installation. Any issues should be fixed as soon as possible using compatible correct fire rated components.
Test door mass 8 grades related to single axis hinges are identified in this european standard as shown in this table. Digit 5 safety in use. Digit 4 fire resistance. Hollow metal swinging fire door selection guide at hörmann we are equipped to offer fire doors tested and certified to american and british standards.
Do get accredited professionals to install your fire doors. Digit 7 security. 200 000 test cycles for medium heavy and severe duty hinges on doors only. This may form part of the risk assessment for the building.
If devices are fitted to fire doors protecting the means of escape then the automatic fire smoke detectors should be positioned in accordance with british standard 5839 part 1 type l3 system as minimum for example suitable detectors on the escape routes and in adjacent rooms opening onto those routes. Standards installers of timber fire doors and those responsible to oversee the installation of fire doors should be familiar with bs 8214. British part 2 bs 476 parts 20 22. Fire door furniture and ironmongery.
Digit 6 corrosion resistance. The old british standard bs 7352 1990 which categorised hinges into 9 classes depending on door mass and frequency of use has been replaced by bs en 1935 2002 which has an 8 digit classification scheme. Fire doors are engineered products that provide life and property saving functions in the event of fire. Check your door s certification look for british standard bs parts 22 and 31 or bs en 1154.
1987 fire tests on building materials and structures. 2016 timber based fire door assemblies. Fire door inspection and maintenance. The significant requirements of each of these standards are listed below.
Not suitable for fire smoke resistant door assemblies. This standard is referenced in most fire door certificates and provides further information about fire door installation. Building regulations 2000 fire safety part b. Suitability for fire smoke door use 2 grades identified.
Maintenance of fire doors.